June 25, 2014

the remaining 20’ for the Air compressor which is comprised of a Sullair 1525 SCFM at 350 psig GENERON designed and built utilizing a C-32 Caterpillar ATEX Directive 930 Horse Power, PyroBan Water Cooled Diesel Engine. This system is designed for use in Hazardous Areas. The Crash Frame Design along with the 10’ Enclosed Membrane System allows easy access in order to perform the maintenance on the unit and keeps the membrane system protected from the harsh environments in Nigeria.

The Booster is Housed in the Second Crash Frame built to DNV 2.7.1 and utilizes an L20’ x H9’ 6” x W8’ section of the 30’ Crash Frame. The GENERON Class1 Zone 2 Booster Utilizes A Caterpillar C-9 ATEX Directive 390 Horse Power PyroBan Water Cooled Diesel Engine. The C-9 Caterpillar Engine drives an Ariel JGQ2 Booster that is designed for 350 psig suction pressure and a final discharge of 3000 psig. There is also an 800 gallon Fuel tank built into this section of the Crash Frame. The remaining 10’ of the Crash Frame serves as an Office with a built in Work Station, Over Head Storage Cabinets, a Desk and 2 Tool Boxes. The Office/ Work Station also have a Class1 Zone 2 12000 BTU Wall Mount Air Conditioner.

In addition to the GENERON components, Houston Vessel Manufacturing, an affiliated company, supplied the vessels and filters for the package.